summary
Claims nanosecond-level synchronization using Stanford’s Hygens algorithm that runs in NICs, sends probes to ~10–20 peers and synchronizes every 2 seconds. It removes noisy measurements with coded probes, fits bounds with support vector machines, and resolves loop inconsistencies with a network-effect minimum‑norm solve. Tests report ~12–15 ns average and 30–45 ns 99th percentile at 40% load, ~16–23 ns average and 45–48 ns 99th at 90% load, using ~0.5% bandwidth and <4% CPU on a 40 Gbps fabric.