Shows actual test numbers and failures or passes for the Generic Node: radiated power 2.5 dBm (limit 14 dBm), occupied bandwidth 125 kHz, emissions measured up to 6 GHz with harmonics at 3.47 and 4.34 GHz below limits, immunity at 3 V/m (and extra checks at 10 V/m) and ±8 kV ESD contact/air pulses with no loss of LoRa communication, temperature cycling -10°C to +55°C and supply 2–5.5 V. If specifics and test methods matter, this is useful.