EU Regulatory approval with Generic Node
summary
Shows actual test numbers and failures or passes for the Generic Node: radiated power 2.5 dBm (limit 14 dBm), occupied bandwidth 125 kHz, emissions measured up to 6 GHz with harmonics at 3.47 and 4.34 GHz below limits, immunity at 3 V/m (and extra checks at 10 V/m) and ±8 kV ESD contact/air pulses with no loss of LoRa communication, temperature cycling -10°C to +55°C and supply 2–5.5 V. If specifics and test methods matter, this is useful.
AI-written summary · about
chapters (19)
- 0:00Introduction
- 2:40Radio Equipment Directive
- 9:35EC testing
- 18:37radiated immunity testing
- 19:47radio testing
- 20:23radiated spurious emissions
- 20:44radio spurious emissions
- 22:08unwanted emission
- 23:17radiated power
- 24:05occupied bandwidth
- 25:06temperatures
- 26:09electrical safety
- 28:35product safety
- 29:00persons
- 30:32classes
- 31:00safeguards
- 32:49hazard identification
- 33:37limits
- 34:51outro
related talks
27mLoRaWAN Modules Analysis
31mThe Challenge of LoRaWAN Antennas
53mBecome a Wireless Connectivity Ninja 101
15mSaiyan: Design and Implementation of a Low-power Demodulator for LoRa Backscatter Systems
15mDemonstration of GNU Radio Compatibility with a NASA Space...
16mNR-Surface: NextG-ready µW-reconfigurable mmWave Metasurface
17mSelecting your LoRa IC for your application
30mLoRaWAN From Space
