Ceph: Lessons Learned from Emergency Support
summary
Emergency support cases across two–three years show concrete fixes and anti-patterns: a three‑OSD cluster is migrated to ~100 OSDs without downtime; RAID controller firmware reboots take 14 months to fully resolve; an OSD memory‑leak bug takes six months to land in release; PG autoscaler often misbehaves so teams disable and predefine PGs; avoid journal cache tiering (deprecated), prefer replication factor 3 with four nodes for safety, run burn‑in tests, monitor deep‑scrub CPU and monitoring DB growth, and use three monitors for ~500 OSDs.
AI-written summary · about
chapters (25)
- 0:00Introduction and background
- 1:52Common Ceph setups and versions
- 3:19Performance issues and migrations
- 4:45MDS service and scaling challenges
- 6:30Automation and data distribution
- 8:17Hardware pitfalls and vendor issues
- 10:02Multi-site and journaling trade-offs
- 11:28Feature selection and workloads
- 12:52PG Auto Scaler and performance
- 13:55Cache tiering and deprecated features
- 14:36Data loss risks and recovery
- 16:01Lift and shift misconceptions
- 17:26Monitoring and resource consumption
- 18:30Large cluster strategies
- 21:17Cluster sizing and support teams
- 24:41Q&A: MDS count and active replay
- 27:10Q&A: Minimum OSD and hardware sizing
- 29:01Q&A: Replication factor and disk failures
- 30:46Q&A: Detecting disk degradation
- 32:18Q&A: Large HDD recovery challenges
- 36:25Q&A: Scaling clusters manually
- 37:51Q&A: Optimal monitor count
- 40:27Q&A: Cache tiering risks
- 42:37Q&A: HDD clusters with SSD caching
- 43:19Closing remarks